You have no items in your shopping cart.
DOWNLOAD SPEC SHEET          DOWNLOAD USER MANUAL
----------------------------------------------------------------------------------------------------------------------------------------------------
Mr. Heater Hi-Intensity Inrared Heater
Mr. Heater Vent Free High Intensity heaters provide heat through an infrared "radiant" heat process, without the need for outside venting. Infrared “radiant” heaters provide heat by instantly adding warmth to you and objects in the room just like the sun. Think of a cat on a windowsill! Radiant heaters project warmth into the room like sunlight through a window.
High Intensity heaters are ideal for buildings with high ceilings, hard to heat areas, or buildings which require only spot heating are more effectively heated using high intensity infrared heaters.
Because high intensity heaters are "vent free", they do not required outside venting and are 99.9% fuel efficient. Because they don’t require outside venting, no heat is lost.
Infrared Described
Infrared heaters work the same way that the sun does. Infrared rays heat the object directly, not the air around it. When the object becomes hot, it heats the surrounding air and any other objects. With infrared heat, people, machinery, objects and floors all become heat reservoirs -- leading to greater fuel and cost efficiency. It's the perfect heating solution to large buildings like warehouses, machine and auto body shops, terminals, manufacturing plants and farm building
Product Features
• CSA certified ANSI Standard Z83.7/CGA 2.14-2000.
• Heats up to 500-600 sq. ft. (2-1/2 car garage)
• For use in low profile buildings with 7-8 ft. ceilings
• No electricity required – heats during power outages
• Includes thermostat
• All necessary brackets and hardware included
• Available in propane (22,000 BTU/Hr.) or natural gas (25,000 BTU/Hr.)
| Model Name | Garage Heater |
| Manufacture | Mr. Heater |
| User Guide | DOWNLOAD USER MANUAL |
| Product Specs | DOWNLOAD SPEC SHEET |
| Model/SKU # | MH25 |
| UPC Code | 089301-72100-5 |
| Low BTU Rating | N/A |
| Medium BTU Rating | N/A |
| High BTU Rating | 22000 BTU/hr |
| Valve Positions | Pilot - Hi Output |
| Average Heating Area | 500 Sq Ft |
| Gas Types Supported | Propane |
| Cylinder Size Supported | 100 Lb Tank Minimum |
| Ignition Type | Match Light |
| Heat Type | Radiant Heater |
| Blower Fan Included? | N/A |
| Blower Fan Operation | N/A |
| Electricity Requirement | None Required |
| Clearance Below Heater | 48 Inches |
| Clearance From Ceiling | 14 Inches |
| Clearance In Front | 16 Inches |
| Clearance In Rear | 16 Inches |
| Clearance On Sides | 16 Inches |
| Thermostat Type | Included |
| Low Oxygen Shutoff Pilot (ODS) | N/A |
| Burner Guard | High Temp Steel |
| Regulatory Approvals | CSA 4.98 U.S. (for use in Califonia) |
| Warranty | 1 Year Manufacture Warranty |
| Dimensions | 29.34"L x 12.25"w x7"H |
| Weight | 20 Lbs |
No questions asked yet